Copyright © Wuhan Yunzhou Seiki lntelligent Control Technology Co.,Ltd. All rights reserved. Site Map
QJR6-1400H basic specifications | |||
Organizational form | Vertical multi-jointed | ||
Degrees of Freedom | 6 | ||
Payload | 6kg | ||
Wingspan | 1461mm | ||
Repeatability^2 | ±0.08mm | ||
Mechanical limit range | 1-axis | ±174° | |
2-axis | +159°,-93° | ||
3-axis | +95°,-125° | ||
4-axis | ±183° | ||
5-axis | +129°,-126° | ||
6-axis | ±360° | ||
Maximum speed | 1-axis | 4.1 rad/s | 235°/s |
2-axis | 4.1 rad/s | 235 °/s | |
3-axis | 4.2 rad/s | 240°/s | |
4-axis | 6.3 rad/s | 361 °/s | |
5-axis | 6.3 rad/s | 361°/s | |
6-axis | 17 rad/s | 974 °/s | |
Permissible torque | 4-axis | 28 N.m | |
5-axis | 14.4 N.m | ||
6-axis | 5 N.m | ||
Moment of inertia | 4-axis | 1.2 kg.m² | |
5-axis | 0.8 kg.m² | ||
6-axis | 0.1 kg.m² | ||
Weight | 150 kg | ||
Installation Environment | Temperature | 0~45 ℃ | |
Humidity | 20%~80%RH(no condensation) | ||
vibration | <4.9m/s²(0.5G) | ||
other | Avoid flammable and corrosive gases and liquids; Avoid contact with water, oil, dust, etc.; Do not approach electrical noise sources. | ||
Power capacity | 2.6kVA | ||
Installation | Ground installation, hanging installation |