QJR6-1 basic specifications | |||
Organizational form | Vertical multi-jointed | ||
Degrees of Freedom | 6 | ||
Payload | 6kg | ||
Wingspan | 1441mm | ||
Repeatability^2 | ±0.03mm | ||
Mechanical limit range | 1-axis | ±168° | |
2-axis | +150°,-86° | ||
3-axis | +87°,-110° | ||
4-axis | ±170° | ||
5-axis | ±125° | ||
6-axis | ±360° | ||
Maximum speed | 1-axis | 3.5 rad/s | 200.5°/s |
2-axis | 3.1 rad/s | 177.6/S | |
3-axis | 3.5 rad/s | 200.5/s | |
4-axis | 7.5 rad/s | 429.7/s | |
5-axis | 7.5 rad/s | 429.7/s | |
6-axis | 10.5 rad/s | 601.6/s | |
Permissible torque | 4-axis | 28 N.m | |
5-axis | 28 N.m | ||
6-axis | 26.4 N.m | ||
Moment of inertia | 4-axis | 1.1 kg.m² | |
5-axis | 1 kg.m² | ||
6-axis | 0.7 kg.m² | ||
Weight | 170 kg | ||
Installation Environment | Temperature | 0~45 ℃ | |
Humidity | 20%~80%RH(no condensation) | ||
Vibration | <4.9m/s²(0.5G) | ||
Other | Avoid flammable and corrosive gases and liquids; Avoid contact with water, oil, dust, etc.; Do not approach electrical noise sources. | ||
Power capacity | 2.9kVA | ||
Installation | Ground installation, hanging installation |